1. OPN open push button
2. CLS close push button
3. PED pedestrian open push button
4. STP stop push button
5. Gate status display, open green, close red
6. Mode selection DIP switch
7. Close motor force( reverse power)
8. Control inputs terminals.
9. Accessary power supply12V/24V
10. Lock output relay
11. M1 output
12. M2 output
13. Motor protect fuse
14. Battery terminals
15. Power supply 12 V or 24V AC.

2.2 Control inputs

2.2.1 OSC input
If DIP4 is off, without auto close; OSC input is in cycle (open—stop—close—open). If DIP4 is on,
OSC input will be open only.
2.2.2 Pedestrian Access (PED) input
If DIP4 is off, without auto close; OSC input is in cycle (open—stop—close—open), open M1
only. If DIP4 is on, OSC input will be open only. OSC will override PED function.
2.2.3 Photoelectric safety beam (PE) input (N/C type)
If the P.E input is activated while gate is closing, the controller will stop the gate or reopen the
gate depending on the DIP setting. If the gate in the opened position and P.E beam is activated, the
gate will stay in opened.
2.2.3 Open button --- Open gate and set timers while in setting model.
2.2.4 CLS button --- Close gate and set timers while in setting model.
2.2.5 PED button --- Same as PED input set timers while in setting model.
2.2.6 STP Button --- Stop gate and set timers while in setting model.
2.4 Model Select Switch (8)
2.4.1 SET (DIP1)
DIP1 is on: Set model. . DIP1 is off, run model.
2.4.1 SYNC Delay (DIP2)
DIP2 is on: Motor 2 delay open and motor 1 delay close. DIP2 is off, there is no delay. Not apply to
Torque motor.
2.4.5 LOCK (DIP3)
DIP3 on, the lock output is presence. The lock relay will be on if the gate is in opening, closing cycle.
DIP3 is off; lock output is 0.8 seconds pulse at the start of each open and close cycle.
2.4.6 Auto CLS (DIP4)
ON= Set
OFF= Run
ON= Delay
ON= presence
ON=AUTO CLS
- 3 -
OFF= No Delay
OFF= pulse
OFF=NO AUTO CLS (30sec))