STATUS LED/TEST SWITCH
BOARD REPLACEMENT :
After the unit is opened disconnect the connector from Test
switch /Status LED board assembly, flex the snap at one
side remove Test switch/Status LED board from plastic
cover carefully. Replace new Test switch/Status LED board
and push the board towards plastic cover carefully. Ensure
that board is properly assembled then connect connector
and close the unit.
.
To remove IR board, release snaps
DC Input wire details
White with Red stripe: Positive (+)
White with Black stripe: Negative (-)
AFFINITY
MAINTENANCE and WIRING DIAGRAM
Connector
®
LIFE SAFETY SOLUTIONS
TEL: 800-705-SERV (7378)
Federal Communications Commission (FCC) Requirements:
This device complies with FCC Title 47, Part 15, Subpart B. this
device does not cause harmful interference.
"
"
Forward/Wide
button
WIRING DIAGRAM
WT Lamp
www.lithonia.com
Fig 1
FCT Lamp
WT Lamp
© 2020, Acuity Brand Lighting,Inc.
Page 5
Status LED/
Test Switch/
Infrared
activator Board
912-00021-002
Rev. CA, 2/2020
All Rights Reserved.