9. Anti mask
The EDS-2000AM has a sophisticate anti mask module:
This module is assembled on the EDS2000AM main board.
To activate the AM please pull up SW2 position 2 and remove the PET optic filter.
The EDS2000AM has aambient light sensor.
The EDS2000AM made self calibration for the anti mask 30 minutes after power up.
Please be verify during installation that the EDS2000AM is closed well before 30 minutes
from power up.
If the first power up is under direct sunlight the EDS2000AM will made the self calibration
30 minutes after the sun light intensity will decrease
10
Operation
Note! Connect the EDS-2000AM to a positive Voltage output of 9.6 -16VDC
source.
Use only a listed power limited source.
The detector shall be provided with minimum of 4 hours of standby power from either a
listed compatible control unit or power supply.
The detector is automatically operated once connected to power.
The LEDs start flashing one at a time (side to side) for 30 seconds during the warm-up
period and after that it will turn off.
At this time the detector is ready for operation.
P/N: 7101796A