8.3 Pet immunity setting
The EDS-2000-AM has a detachable Pet immunity filter. As such the Pet immunity level may
vary between:
1. 36kg (80 lbs) with pet immunity filter assembled
2. 15kg (33 lbs) if no pet immunity filter is used.
Note: Adding the detachable Pet immunity filter will cause anti mask alarm. In order to use the filter,
turn off the anti-masking feature (SW2-position 2: OFF).
This option is not suitable for EN50131-2-4 complient installation.
You can apply an electric pet immunity by pulling SW2-position 4 to ON position.
The installer is to select the requested Pet immunity level.
The filter is to be installed according to the following orientation:
This side up!