ABB DCS800-S01-0315-05 Manuel du micrologiciel - Page 3
Parcourez en ligne ou téléchargez le pdf Manuel du micrologiciel pour {nom_de_la_catégorie} ABB DCS800-S01-0315-05. ABB DCS800-S01-0315-05 20 pages.
Revision Information
This supplement is dedicated to Revision 2.6 and Revision 2.7 of the DCS800 Firmware.
Drives shipped after March, 2008 will most likely have this revision.
What revision do I have?
To determine your firmware revision number, check the value of signal:
FirmwareVer (4.01).
Or check the label on the box:
Indicates Revision 2.6
What's different with this revision
1. New Macros: Four new macros have been added. See details later in this
supplement.
2. Date display in control panel data logger: The data logger now correctly displays the
date and time of the fault.
3. Autotuning field current controller assistant: Autotuning now works when both field
exciters are enabled.
4. Nuisance A131 ParAdded: This alarm was seen sometimes after drive is energized.
This has now been corrected.
5. RdyOn with RDIO: When energizing the drive and using a RDIO, the signal RdyOn
(MainStatWord 8.01) came on too early.
6. DC Voltage Measurement: Overflow protection has been added. This was needed
for electromagnet control.
7. DC Nom Current: A fault is now set when M1NomCur (99.03) is set to zero.
8. Autotuning Speed Controller: This autotune tripped when M1MinSpeed (20.01) or
M1MaxSpeed (20.02) was set to zero. This has now been corrected.
9. Bumpless transition: When changing torque selector (26.01) from MIN/MAX to
SPEED, you will now see a bumpless transition.
DCS800 Firmware manual supplement for North America (rev. 2.60, 2.70) Rev. b
3
5/30/2008