2-10
Step 1.
Mount Capacitor
(0.5µF Coaxial Type)
under generator ground screw.
Step 1.
Mount Capacitor to
(0.5µF Coaxial Type)
under alternator
ground screw.
Step 3.
Connect wire lead to capacitor
using lockwasher and nut.
Step 2.
Disconnect wire (dashed)
from armature post and
connect to capacitor using
lockwasher and nut.
Figure 2-6 Generator Whine Suppression
Figure 2-7 Alternator Whine Suppression
REDUCING NOISE INTERFERENCE
Step 4.
Connect capacitor
lead to armature post.
Caution:
Do not connect
capacitor to field teminal.
FL0830310-O
Step 2.
Disconnect wire from
battery post and connect
to capacitor using
lockwasher and nut.
Caution:
Do not connect
capacitor to field terminal.
Step 3.
Connect wire lead to capacitor
using lockwasher and nut.
Step 4.
Connect capacitor
lead to battery post.
FL0830311-O