Maintenance
WARNINg: Disconnect all
power coming to fireplace at main
service panel before attempting
maintenance or cleaning to
reduce risk of fire, shock or
damage to persons.
CAUTION:
minutes for light bulbs to cool off
before touching bulbs to avoid ac-
cidental burning of skin.
Tool Requirements: Phillips
screwdriver
Light Bulb Replacement:
Light bulbs need to be replaced
when you notice a dark section
of the flame or when the clarity
and detail of the log exterior
disappears. There are four bulbs
under the log set which generate
the flames and embers.
Helpful Hints: It is a good idea to
replace all light bulbs at one time
if they are close to the end of their
rated life. Group replacement will
reduce the number of times you
need to open the unit to replace
light bulbs. Long life bulbs are
recommended to reduce the
frequency of bulb changes.
Light Bulb Requirements:
Quantity of 4 clear chandelier or
candelabra bulbs with an E-12
(small) socket base, 60 Watt
8
Allow at least 5
rating. Example: GE 60BC or
Philips 60CTC.
DO NOT EXCEED 60 WATTS
PER BULB.
CAUTION: When handling log
only apply force to the ember bed
section not directly to the logs.
To access the light bulb area
1.
open steel curtain (remove
glass doors if applicable).
2.
remove two screws on log
bracket and set aside
(Figure 2)
3.
Pull front edge of plastic
ember bed or plastic grate
up and forward until rear
tab releases from the ledge
located at the bottom of the
mirror (Figure 3).
!
NOTE: Log set fits tightly
into firebox, some force may be
necessary to remove.
Figure 2
screws
www.dimplex.com