Toshiba 13PKCVG-V Manuel du propriétaire - Page 2
Parcourez en ligne ou téléchargez le pdf Manuel du propriétaire pour {nom_de_la_catégorie} Toshiba 13PKCVG-V. Toshiba 13PKCVG-V 8 pages.
PRECAUTIONS FOR SAFETY
Read the precautions
in this manual carefully
before operating the unit.
● Keep this manual where the operator can easily find it.
● Read the precautions in this manual carefully before operating the unit.
● This appliance is intended to be used by expert or trained users in shops, in light
industry and on farms, or for commercial use by lay persons.
● The precautions described herein are classified as DANGER, WARNING and
CAUTION. They both contain important information regarding safety. Be sure to
observe all precautions without fail.
● Do not install, repair, open or remove the cover. It may expose you to dangerous voltages.
Ask the dealer or the specialist to do this.
● Turning off the power supply will not prevent potential electric shock.
● The appliance shall be installed in accordance with national wiring regulation.
● Means for disconnection from the supply having a contact separation of at least 3 mm in
all poles must be incorporated in the fixed wiring.
● The appliance must be stored in a room without continuously operating ignition sources
(for example, open flames, an operating gas appliance or an operating electric heater).
● In order to avoid fire, explosion or injury, do not operate the unit when harmful gases (e.g.
flammable or corrosive) are detected near the unit.
● Do not expose your body directly to cool or warm air for a long time.
● Do not insert your finger or any article into the air inlet/outlet.
● When an abnormality (burning smell, etc.) occurs, stop the air conditioner and disconnect
the power supply or turn off the breaker.
● This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety.
● The air conditioner must be installed, maintained, repaired and removed by a qualified
installer or qualified service person. When any of these jobs is to be done, ask a qualified
installer or qualified service person to do them for you.
● Children should be supervised to ensure that they do not play with the appliance.
● Do not use any refrigerant different from the one specified (R32) for complement or
replacement. Otherwise, abnormally high pressure may be generated in the refrigeration
cycle, which may result in a failure or explosion of the product or an injury to your body.
● Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
● The appliance shall be stored in a room without continuously operating ignition sources
(for example: open flames, an operating gas appliance or an operating electric heater).
● Be aware that refrigerants may not contain an odour.
● Do not pierce or burn as the appliance is pressurized. Do not expose the appliance to
heat, flames, sparks, or other sources or ignition. Else, it may explode and cause injury
or death.
● Appliance and pipe-work shall be installed, operated and stored in a room with a floor area
larger than A
m
.
2
min
How to get A
m
2
: A
= (M / (2.5 x 0.22759 x h
min
min
M is the refrigerant charge amount in appliance in kg. h
the appliance in m: 0.6 m for floor standing/1.8 m for wall mounted/1.0 m for window
mounted/2.2 m for ceiling mounted. (For these units recommend installation height 2.5 m)
● Do not wash the unit with water. It may cause an electric shock.
● Do not use this air conditioner for other purposes such as preserving food, breeding
animal, etc.
● Do not step or put anything on the indoor/outdoor unit. It may cause an injury or damage
the unit.
● Do not touch aluminium fin because it may cause an injury.
● Before cleaning the unit, turn off the main switch or the circuit breaker.
● When the unit won't be used for a long time, turn off the main switch or the circuit breaker.
● It is recommended that maintenance be performed by a specialist when the unit has been
operated for a long time.
● The manufacturer shall not assume any liability for the damage caused by not observing
the description of this manual.
1
INDOOR UNIT DISPLAY
1 TIMER (White)
2 OPERATION (White)
This appliance is filled with
R32.
DANGER
WARNING
))
2
0
is the installation height of
0
CAUTION
2
PREPARATION BEFORE USE
Preparing Filters
1. Open the air inlet grille and remove the air fi lters.
2 . Attach the
fi lters. (see detail in the installation manual).
Loading Batteries (when use wireless operation.)
1. Remove the slide cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (–) positions.
Clock Setup
1. Push
by tip of the pencil.
If timer indication is fl ashing, go to the next step 2.
2. Press
or
: adjust the time.
3. Press
: Set the time.
Remote Control Reset
Push
by tip of the pencil or
1. Remove the batteries.
2. Press
.
3. Insert the batteries.
3
AIR FLOW DIRECTION
FIX
Press
: Move the louver in
1
the desired vertical direction.
SWING
Press
: Swing the air
2
automatically and press again to stop.
For horizontal direction, adjust
3
manually.
Note:
Do not move the louver manually by others.
●
●
The louver may automation positioning by some operation mode.
4
REMOTE CONTROL
1 Infrared signal emitter
2 Start/Stop button
3 Mode select button (MODE)
4 Temperature button (TEMP)
5 Fan speed button (FAN)
6 Swing louver button (SWING)
7 Set louver button (FIX)
8 On timer button (ON)
9 Off timer button (OFF)
! Setup button (SET)
" Clear button (CLR)
# Memory and Preset button (PRESET)
$ One-Touch button (ONE-TOUCH)
% High power button (Hi-POWER)
& Power selection button (POWER-SEL)
( Quiet button (QUIET)
) Comfort sleep button (COMFORT SLEEP)
~ Filter reset button (FILTER)
+ Set clock button (CLOCK)
, Check button (CHECK)
- Reset button (RESET)
Note:
The provided Remote Controller is a wireless type, which also can be
●
used as a wire. Please see "How to Connect The Remote Controller
for Wired Operation", located in installation instruction, in case of wired
control is required.
●
In wire operation, remote controller will return to initial condition (PRESET,
TIMER and CLOCK will return to initial condition) when user shutdown
power supply of Air conditioner.
1
#
4
2
6
3
5
SWING
FAN
7
(
$
ONE-TOUCH
FIX
QUIET
&
%
POWER-SEL
Hi POWER
"
COMFORT
8
9
SLEEP
!
)
,
-
+
~