Toshiba AH8-PE Manuel du propriétaire - Page 12

Parcourez en ligne ou téléchargez le pdf Manuel du propriétaire pour {nom_de_la_catégorie} Toshiba AH8-PE. Toshiba AH8-PE 13 pages. Split type
Également pour Toshiba AH8-PE : Manuel d'entretien (20 pages)

Toshiba AH8-PE Manuel du propriétaire

AIR CONDITIONING OPERATION AND PERFORMANCE

Three-minutes protection feature
A protection feature prevents the air conditioner from being activated for approximately 3 minutes when
it is restarted immediately after operation or when the power supply switch is set to on. This will protect
the machine.
Heating operation characteristics
Preheating operation
The air conditioner will not deliver warm air immediately after it is started.
Warm air flows out after approximately 5 minutes when the indoor heat exchanger warms up.
(The PRE.-DEF. lamp is on during the preheating operation.)
Warm air control
When the room temperature reaches the set temperature, the indoor fan speed is automatically reduced
to prevent cold draughts.
The outdoor unit will stop.
Defrosting
If the outdoor unit is frosting during heating operation, defrosting is started automatically (for
approximately 5 to 10 minutes). To maintain the heating effect, the PRE.-DEF. lamp is on.
The fans on the indoor and outdoor units stop during the defrost operation.
During defrost operation, defrosted water is drained from the bottom plate of the outdoor unit.
Heating capacity
If the outdoor temperature is too low, it is recommended that additional heating appliances be used in
conjunction with the air conditioner.
Power failure
Power failure during operation will stop the unit completely.
The OPERATION lamp (green) on the indoor unit will start flashing when power is restored.
To restart operation, push the START/STOP button on the remote control.
Air conditioner operating conditons
For proper performance, operate the air conditioner in the following temperature conditions:
Cooling operation
Heating operation
If air conditioner is used out of the above conditions, safety protection features may come into
operation.
Outdoor temperature:
Room temperature:
CAUTION
Room relative humidity – less than 80%. If the air conditioner
operates in excess of this figure, the surface of the air
conditioner may attract condensation.
Outdoor temperature:
Room temperature:
12
-5 C to 43 C
18 C to 32 C
-10 C to 21 C
Less than 30 C