Figure 5
!
NOTE: If the surface you are using as a work area on is
a finished surface that is prone to scratches (i.e. hardwood
flooring), it is recommended that a protective barrier be
used underneath, (i.e. cloth, cardboard, thick plastic).
5. Proceed to the instructions within this manual relating
to the repair being performed - see Table of Contents
for page number.
6. Once repair is complete, reassemble in the reverse
order as above.

Recessed Mount - Partial In-wall

(Figure 7)
Tools Required: Phillips head screwdriver
CAUTION: Follow "Preparation for Service" instructions
before proceeding.
1. Remove the decorative acrylic ember-bed pieces from
the media tray, which lies along the bottom of the inte-
rior Partially Reflective Glass. A medium sized con-
tainer such as a bucket or a box will be needed to keep
the acrylic ember-bed pieces together.
2. Locate and remove the 4 mounting screws located
approximately 3 inches deep in the space between the
outer and inner casing on the left and right hand side.
There are 2 screws per side, upper and lower going
into a stud. (Figure 7)
CAUTION: The fireplace should be supported while
removing the screws to prevent the unit from falling.
3. Remove the fireplace out of the opening by slightly lift-
ing and pulling forward.
4. Carefully lay the unit down on a solid flat surface with
the front of the unit facing up.
!
NOTE: If the surface you are using as a work area is a
finished surface that is prone to scratches (i.e. hardwood
flooring), it is recommended that a protective barrier be
used underneath, (i.e. cloth, cardboard, thick plastic).
5. Proceed to the instructions within this manual relating
8
7.0 in.
(179 mm)
19.4 in.
(494 mm)
32.4 in.
(823 mm)
30.0 in.
(761 mm)
34.1 in.
(867 mm)
to the repair being performed - see Table of Contents
for page number.
6. Once repair is complete, reassemble in the reverse
order as above.
Flush Mount – Complete In-wall
(Figure 8)
Tools Required: Phillips head screwdriver
CAUTION: Follow "Preparation for Service" instructions
before proceeding.
1. Remove the decorative acrylic ember-bed pieces from
the media tray, which lies along the bottom of the interi-
or Partially Reflective Glass. A medium sized container
such as a bucket or a box will be needed to keep the
acrylic ember-bed pieces together.
2. Locate and remove the 4 mounting screws inside the
unit located on left and right side towards the front.
Figure 6
Wall Mounting
Bracket
6.8 in.
(172 mm)
3.8 in.
(95 mm)
(406 mm)
Bottom Support
Bracket
16.0 in.
18.0 in.
(457 mm)
www.dimplex.com