Toshiba 255 Manuel d'information sur la sécurité - Page 20

Parcourez en ligne ou téléchargez le pdf Manuel d'information sur la sécurité pour {nom_de_la_catégorie} Toshiba 255. Toshiba 255 34 pages. Multifunctional digital systems

Toshiba 255 Manuel d'information sur la sécurité

1 GENERAL PRECAUTIONS

General Precautions

When installing or moving

e-STUDIO5520C/6520C/6530C
For U.S.A. and Canada
This Multifunctional Digital Systems requires 115 V, 20 A (or 15 A + 20 A), 50/60 Hz electric power.
For EU
This Multifunctional Digital Systems requires 220 to 240 V AC, 13 A, 50/60 Hz electric power.
Except U.S.A., Canada and EU
This Multifunctional Digital Systems requires 220 to 240 V AC, 10 A, 50/60 Hz electric power. For Saudi Arabia 100 V
version, it requires 127 V AC, 20 A (or 15 A + 20 A), 50/60 Hz electric power.
e-STUDIO2330C/2820C/2830C/3520C/3530C/4520C
For U.S.A. and Canada
This Multifunctional Digital Systems requires 115 V, 15 A, 50/60 Hz electric power.
For EU
This Multifunctional Digital Systems requires 220 to 240 V AC, 10 A, 50/60 Hz electric power.
Except U.S.A., Canada and EU
This Multifunctional Digital Systems requires 220 to 240 V AC, 10 A, 50/60 Hz electric power. For Saudi Arabia 100 V
version, it requires 127 V AC, 15 A, 50/60 Hz electric power.
e-STUDIO205L/255/305/355/455
For U.S.A. and Canada
This Multifunctional Digital Systems requires 115 V, 12 A, 50/60 Hz electric power.
For EU
This Multifunctional Digital Systems requires 220 to 240 V AC, 8 A, 50/60 Hz electric power.
Except U.S.A., Canada and EU
This Multifunctional Digital Systems requires 220 to 240 V AC, 8 A, 50/60 Hz electric power. For Saudi Arabia 100 V
version, it requires 127 V AC, 12 A, 50/60 Hz electric power.
e-STUDIO555/655/755/855
For U.S.A. and Canada
This Multifunctional Digital Systems requires 115 V, 20 A, 50/60 Hz electric power.
For EU
This Multifunctional Digital Systems requires 220 to 240 V AC, 9 A, 50/60 Hz electric power.
Except U.S.A., Canada and EU
This Multifunctional Digital Systems requires 220 to 240 V AC, 9 A, 50/60 Hz electric power. For Saudi Arabia 100 V
version, it requires 127 V AC, 20 A, 50/60 Hz electric power.
Do not use a power supply with a voltage other than that specified.
Avoid multiple connections in the same outlet. This could cause a fire or give you an electric shock. If you are
considering increasing the number of outlets, contact an electrician.
Always connect this Multifunctional Digital Systems to an outlet with a ground connection to avoid the danger of fire or
electric shock in case of short-circuiting. Contact your service representative for the details. Be sure to use a 3-
conductor, grounded wall outlet.
In areas, except U.S. and Canada, where a 2-pin plug is used, the Multifunctional Digital Systems must be grounded
for safety. Never ground it to a gas pipe, a water pipe, or any other object not suitable for grounding.
Plug the power cord securely into the outlet. If it is not plugged in properly, it could heat up and cause a fire or give you
an electric shock.
Do not damage, break or attempt to repair the power cord.
The following things should not be done to the power cord.
- Twisting it
- Bending it
- Pulling it
- Placing anything on it
- Making it hot
- Situating it near radiators or other heat sources
This could cause a fire or give you an electric shock. If the power cord is damaged, contact your service
representative.
Do not install the equipment by yourself or try to move it once it has been installed. This could result in an injury or
damage to the device. Contact your service representative if the equipment needs to be installed or moved.
The socket outlet shall be near the equipment and be easily accessible.
Pull out the plug from the outlet more than once a year to clean around the prongs. Accumulating dust and dirt could
cause a fire due to the heat released by electric leakage.
18
General Precautions