Operation
Figure 3
A
D
C
B
E
WARNING: This heater is factory prewired for operation
with the built-in thermostat. THIS HEATER IS NOT TO BE
USED WITH A REGULAR WALL THERMOSTAT.
CAUTION: This heater must be properly installed before
it is used.
The CMH is designed with a two stage heating element that
will turn on and off based on the built-in temperature sensor to
maintain a constant room temperature.
!
NOTE: The element retains heat after shutdown, there is
a built in cool down period of 5 minutes before the fan shuts
off completely.
Manual Controls
(See Figure 3 for display reference)
When power is first supplied to the CMH the Setpoint Tem-
perature will flash in the temperature display area. At any time
either the ✚ or – button can be pressed to have the tempera-
ture setpoint displayed again.
A. Setting/Temperature Display
The CMH is designed to control the temperature of a room
from 41-104°F (5-40 °C). By pressing the ✚ or – will increase
or decrease the desired temperature for the room to be heated
by 0.5° (in either °C or °F).
When adjusting the Setpoint Temperature the display will
switch back to display the ambient temperature after 5 sec-
onds.
!
NOTE: The unit can be set to run continuously as a fan by
setting the temperature at 41 °F (5 °C). At this temperature
the heater will not turn on.
!
NOTE: Pressing the ✚ and – at the same time will toggle
between °C and °F.
B. Comfort Setting
The Comfort Setting icon will be displayed when the heater
is in normal operation based on the Setpoint Temperature for
the room.
!
NOTE: Either the
pendent on the setting being used.
C. Economy Setting
The Economy Setting can be used to change the Setpoint
Temperature for a user determined period of time. By pressing
the V the Economy Setting will be enabled - signified by the
A - Setting/Temperature Display
B - Comfort Setting Icon
C - Economy Setting Icon
D - Set Back Temperature Setting
E - Synchronized Icon
F - Lock Icon
G - Decrease Button
H - Increase Button
I - Menu Button
H
G
I
F
or
icon will always be visible, de-
icon flashing. After the Set Back Temperature has been set,
the icon will become solid after three seconds and the Set
Back Temperature will be enabled.
To return back to the Comfort Setting press the V button. The
icon will disappear and the
D. Set Back Temperature Setting
The Set Back Temperature Setting is used during periods
when the Economy setting feature is active. This temperature
adjustment can be set by pressing the V followed by the ✚ or
–.
E. Synchronized Icon
The CMH features CONNEX
works with Dimplex single and multi-zone CONNEX
lers to provide simple whole home connectivity and comfort.
CONNEX
controllers are available to control one or multiple
TM
CONNEX
series heaters within a 50' (15 m) radius. In order
TM
for the controller to have this function the CMH and the con-
troller will need to be synchronized. To do this:
1. On the CMH press and hold the V button for 3 seconds,
both the
and
2. Press the – , ✚ and then V, on the CMH.
3. Within 10 seconds press any button once on the
CONNEX
Controller.
TM
!
NOTE: There is a 3 second delay between pressing the last
button on the controller and the CMH.
!
NOTE: To desynchronize a CMH from the synchronized
CONNEX
Controller; on either the CMH or the controller:
TM
1. Press and hold the V for 3 seconds.
2. Press the V, ✚ and then –.
Nothing will need to be done to the other component.
Dimplex single and multi-zone CONNEX
separately and are available for purchase from your autho-
rized Dimplex dealer.
To find your local Dimplex dealer, visit www.dimplex.com.
F. Lock Icon
The CMH has a Lock feature to prevent settings from acciden-
tally being changed.
1. Press and hold the V for 3 seconds. Both the
Icons will begin to flash.
2. To Enable: Within 5 seconds press ✚, then –, then ✚,
then –. The
icon will appear
To Disable: Within 5 seconds press –, then ✚, then –,
then ✚. The
icon will disappear.
!
NOTE: The CMH can be locked in either the Comfort or
Economy Setting. Ensure that the desired icons are present
when locking is complete.
Boost Function
The CMH is also equipped with a "Boost Function" which al-
lows the user to run the unit at full heat, for a predetermined
amount of time, to quickly heat up a cold room/space. The
Boost can be set for a maximum of 20 minutes, in 5 minute
increments.
To enable Boost:
1. Press and hold ✚ for 5 seconds. The area where the tem-
perature normally displays will begin to toggle between
icon will appear.
, a wireless technology that
TM
icons will begin to flash.
controllers are sold
TM
control-
TM
and
3