Operation Instructions
1. Plug in.
2. To bathe large breeds or older dogs, step on the down pedal to lower the tub and open the
front door. To bathe small breeds, step on the up pedal to raise the tub to a suitable level for
user's stature (and/or by adding a booster rack).
3. Start the bath.
4. After the bath, let the water out of the tub and take the animal out.
5. Unplug the tub and clean it with a cloth.
Parts Replacement
Electric Motor Replacement
1. Disconnect the power cord from the wall socket. Remove the tub/tabletop from the frame
assembly, and set it aside. Remove the grooming arm.
2. Disconnect the electric motor cable from the motor control unit. Remove the snap rings and
the retaining bolts that hold the electric motor to the frame assembly. (See Figure 1 and 2)
3. Using help, lift he frame assembly up, and remove the entire motor assembly from the
frame.
4. Install the new motor assembly in the reverse order. Reconnect the cable to the motor
control unit.
5. Plug the power cord into a wall socket and test the tub/table for proper operation.
Electric motor mount
snap ring
Figure 1
Control Pedal Peplacement
1. Disconnect the powder cord from the wall socket.
2. Remove the three screws holding the control pedal to the frame assembly.
3. Disconnect the control cable connector from the motor control unit. (See Figure 3)
4. Install a new pedal in the reverse order, and re-connect the cable to the motor control unit.
Electric motor
mount
Figure 2
- 6 -
5. Plug the power cord into a wall socket and test the table for proper operation.
Figure 3
Transformer Replacement
1. Disconnect the powder cord from the wall socket.
2. Disconnect the power cable connector from the control pedal. (See Figure 4)
Figure 4
3. Disconnect the control cable connector from the electric motor unit. (See Figure 5)
Figure 5
4. Take the transformer off the mounting rack. (See Figure 6)
5. Install a new transformer in the reverse order。
Figure 6
- 7-