Aries FilterWorks HPL-RO Manuel d'installation et d'entretien - Page 6
Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'entretien pour {nom_de_la_catégorie} Aries FilterWorks HPL-RO. Aries FilterWorks HPL-RO 7 pages. Reverse osmosis system
Troubleshooting:
1. Problem: Not enough product water pressure
Reason: Storage tank air pressure is low
Solution: Empty storage tank and set pressure to 55kPa (8 psi)
2. Problem: Not Enough Water
Reason: Water supply is blocked
Solution: Clear restriction or check water supply
Reason: Storage tank is depleted
Solution: Consider an increase in tank size or membrane capacity
Reason: Clogged sediment cartridge
Solution: Replace sediment cartridge, drain tank, and sanitize system
Reason: Low water pressure
Solution: If line pressure is below 2.1 bar (30 psi), install a booster pump.
3. Problem: No drain water
Reason: Clogged flow restrictor
Solution: Replace membrane
Spare Parts:
Part Number: AFK-005
Replacement Filter Kit (5.0 micron filter, GAC, 1.0 micron filter)
Part Number: AM-12-7010
Membrane: TFC 100 GPD, Residential style
M-0221201113
Revision 4
Page 6 of 7