Ariklima PD70-LAE Manuel de l'utilisateur - Page 2
Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Ariklima PD70-LAE. Ariklima PD70-LAE 4 pages.
a person responsible for their safety. Children should
be supervised to ensure that they do not play with the
appliance.
12. Please keep the product from the wall or other
barriers in a minimum distance of 50 cm.
13. Please install the appliance following the country
wiring laws.
OPERATING INSTRUCTION
1. Control panel
2. Air outlet
3. Handel
4. Front housing
5. Air Inlet / Back housing
6. Drain hole
7. Water tank
2
CONTROL PANEL DESCRIPTION
OPERATING INSTRUCTION
1. Power
Press the key to turn "on" or "off".
2. Fan Speed
Press the key to choose high speed (HI) or low speed (LOW).
3. Timer
a. Press the key to set time you need (1 to 24 hours), and then the related
idicating light will illuminate.
b. When setting timer in stand-by mode, the unit will be turned on
automatically; when setting timer in operating mode, the unit will be turned
off automatically.
c. If pressing the power key to turn on/off the unit before time finishes
counting down, the setting timer will be canceled.
4. Humidity Setting
Press the key to set the relative humidity you need. (From RH50%, 60%,
70%, 80%, comfort mode [AU], to continuous dehumidification [CO].
When ambient humidity is lower than setting humidity by 3%,
compressor will stop automatically, and return working until the ambient
humidity is higher than setting humidity by 3%.
Comfort Mode [AU]
a. When ambient temperature is lower than 5℃, compressor will stop
working.
3