LIgHT BULB REPLACEMENT

CAUTION: If unit was operating prior to servicing allow
at least 5 minutes for lights to cool off to avoid accidental
burning of skin.
WARNINg: Disconnect power before attempting any
maintenance to reduce the risk of electric shock or damage
to persons.
Light bulbs need to be replaced when you notice a dark
section of the flame or when the clarity and detail of the log
exterior disappears. There are three bulbs under the log
set which generate the flames and embers.
HELPFUL HINTS: It is a good idea to replace all light bulbs
at one time if they are close to the end of their rated life.
Group replacement will reduce the number of times you
need to open the unit to replace light bulbs.

UPPER LIgHT BULB REPLACEMENT

UPPER LIgHT BULB REQUIREMENTS: Quantity of 1
clear chandelier or candelabra bulbs with an E-12 (small)
socket base, 7 watt rating.
1.
Open door by pulling the handle.
2.
Locate the upper bulb bracket.
3.
Bend light retainer bracket down.
4.
Locate and remove the light bulb.
5.
Insert new bulb.
6.
Bend light retainer bracket back into its original posi-
tion.
7.
Close the door.

LOWER LIgHT BULB REPLACEMENT

LOWER LIgHT BULB REQUIREMENTS: Quantity of 2
clear chandelier or candelabra bulbs with an E-12 (small)
socket base, 60 watt rating.
1.
Open door by pulling the handle.
2.
Remove the 2 screws from the logset grate located in
front of the emberbed and remove the grate from the
unit.
3.
Remove the logset from the unit by pulling forward and
Figure 3
Figure 4
lifting out.
4.
Locate and examine the bulbs to determine which
bulb(s) required replacement.
5.
Locate and remove the light bulb(s).
6.
Insert new bulb(s).
7.
Install the logset into the unit, and re-install the logset
grate.
8.
Close the door.

FLAME ROD REPLACEMENT

WARNINg: If the stove was operating prior to servic-
ing, allow at least 10 minutes for light bulbs and heating
elements to cool off to avoid accidental burning of skin.
WARNINg: Disconnect power before attempting any
maintenance to reduce the risk of electric shock or damage
to persons.
1.
Open door by pulling the handle.
2.
Remove the 2 screws from the logset grate located in
Figure 5
7