Operation

Figure 1
The manual controls for the log
grate are located in the front right
side. (Figure 1)
A. On/Off Switch
supplies power to the Log Grate.
B.
Momentary Button
Pressing this button toggles
between Logs and Logs and
Heat.
Resetting the Temperature
Cutoff Switch
should the heater overheat, an
automatic cutout will turn the
heater off and it will not come
back on without being reset. It
can be reset by switching the on/
off switch to off and waiting 5
minutes before switching the unit
back on.
B
a
CAUTION: If you need to
continuously reset the heater,
unplug the unit and call Dimplex
north america Limited at
1-800-668-6663.
Remote Control
The fireplace is supplied with a
radio frequency remote control.
This remote control has a
range of approximately 50 feet
(15.25m). It does not have to be
pointed at the fireplace and can
pass through most obstacles
(including walls). It is supplied
with one of 243 independent
frequencies to prevent
interference with other units. The
frequency designation is indicated
on the back of the remote control.
11