Aeon Labs Aeotec Water Sensor 6 Manuel - Page 10
Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Aeon Labs Aeotec Water Sensor 6. Aeon Labs Aeotec Water Sensor 6 12 pages. Z-wave water sensor
2.
When the current measurement >= (Lower limit + Recover limit),
the lower limit report is enabled and then it would send out a
sensor report when the next measurement is less than the lower
limit. After that the lower limit report would be disabled again until
the measurement >= (Lower limit + Recover limit).
3.
High byte is the recover limit value. Low byte is the unit
(0x00=Celsius, 0x01=Fahrenheit).
4.
Recover limit range: 1.0 to 25.5
to 0xFF01).
E.g. The default recover limit value is 2.0
the measurement is less than (Upper limit – 2), the upper limit report
would be enabled one time or when the measurement is more than
(Lower limit + 2), the lower limit report would be enabled one time.
0x40 (64)
Set the default temperature unit.
0 = Celsius unit.
1 = Fahrenheit unit.
0x54 (84)
The state of tilt sensor
0 = the Water Sensor main unit is in horizontal direction.
1 = the Water Sensor main unit is in vertical direction.
Note: this parameter is a Get-only parameter.
0x56 (86)
Enable/ disable the buzzer.
0 = disable.
1 = enable.
0x57 (87)
To set which sensor is triggered the buzzer will alarm.
1 = If the Water leak is triggered, the buzzer will alarm.
2 = If the vibration is triggered, the buzzer will alarm.
4 = If the tilt sensor is triggered, the buzzer will alarm.
16 = If the under heat is triggered, the buzzer will alarm.
32 = If the overheat is triggered, the buzzer will alarm.
Note: if the value = 1+2+4+16+32=55, which means if any sensor is
triggered, the buzzer will alarm.
0x58 (88)
To set which value of the Basic Set will be sent to the associated
nodes in association Group 3 when the Sensor probe 1 is triggered.
0 = Send nothing.
1 = Presence of water, send Basic Set 0xFF, absence of water, send
Basic Set 0x00.
2 = Presence of water, send Basic Set 0x00, absence of water, send
Basic Set 0xFF.
0x59 (89)
To set which value of the Basic Set will be sent to the associated
nodes in association Group 4 when the Sensor probe 2 is triggered.
0 = Send nothing.
1 = Presence of water, send Basic Set 0xFF, absence of water, send
Basic Set = 0x00.
2 = Presence of water, send Basic Set 0x00, absence of water, send
Basic Set 0xFF.
0x5E (94)
To set which power source level is reported via the Battery CC.
0 = report the USB power level.
℃
/
℉
(0x0100 to 0xFF00 or 0x0101
/
(0x1400/0x1401), when
℃
℉
Page 10
US version: 0x01
1
Other versions: 0x00
-
1
1
1
55
1
0
1
0
1
0
1