If you're using a Z-Stick:
1.
If your Z-Stick is plugged into a gateway or a computer, unplug it.
2.
Take your Z-Stick to your MultiSensor.
3.
Press and hold the Action Button on your Z-Stick for 3 seconds
and then release.
4.
Press the Action Button on your MultiSensor.
5.
If your MultiSensor has been successfully removed from your
network, the RGB LED will be active with a colourful gradient for
3 seconds. When you press the Action Button on the MultiSensor,
its green LED will blink. If the removal was unsuccessful, the
green LED will stay solid for a few seconds when you press the
Action Button.
6.
Press the Action Button on the Z-Stick to take it out of removal
mode.
If you're using a Minimote:
Remove
12
1.
Take your Minimote to your MultiSensor.
2.
Press the Remove Button on your Minimote.
3.
Press the Action Button on your MultiSensor.
4.
If your MultiSensor has been successfully removed from your
network, the RGB LED will be active with a colourful gradient for
3 seconds. When you press the Action Button on the MultiSensor,
its green LED will blink. If the removal was unsuccessful, the
green LED will stay solid for a few seconds when you press the
Action Button.
5.
Press any button on your Minimote to take it out of removal
mode.
Monitoring motion.
The MultiSensor can send Basic Set Command to association
group 1, which is setup via the Association Command Class, when
the Motion Sensor detects movement to control the associated
devices to "OPEN" state. After 4 minutes by default, if the Motion
Sensor is not triggered again, the MultiSensor will send Basic Set
Command to these devices to set them to their "CLOSE" state.
However, if the Motion Sensor is triggered again within 4 minutes,
the MultiSensor will reset the timing and start timing again.
The 4 minutes delay time can be changed through the usage
of Z-Wave commands built into Z-Wave certified controllers/
gateways. (The specific Z-Wave command supporting this function
is Configuration Command Class) Please consult the operation
manual for these controllers/gateways for specific instructions on
configuringthe MultiSensor.
13