10. CONTROL BOARD Cont.
WARNING - ELECTRICAL SHOCK
The Control Board Heat Sink will remain charged for five (5) minutes after power is disconnected from the appliance. To
avoid electrical shock DO NOT come in contact with the Control Board until the appliance has been removed from live
current for at least five (5) minutes, and the Heat Sink has had an opportunity to discharge.
• With the four Control Board mounting screws and the Capacitor Nut removed you can now carefully remove the individual wire
connections from the Board, and then remove the Control Board from the unit (Fig. 10-2).
IMPORTANT: WIRE CONNECTORS CAN ATTACHED TO THE CONTROL BOARD IN MANY LOCATIONS. ALWAYS MAKE
SURE TO NOTE THE WIRE HARNESS LOCATION OF EACH CONNECTOR BEFORE REMOVING IT FROM THE
CONTROL BOARD. THIS WILL INSURE THEY ARE RETURNED TO THEIR CORRECT LOCATIONS.
REPAIR MANUAL
WARNING
WARNING
AW 129 NA / AW 149 NA
Fig. 10-2
Page: 11