Assembly of clusters using the CP-XY12DF1 Dual Enclosure Flying Plate set
Attachment of wall mount brackets
! Four holes (M8) for wall mount brackets are provided on the rear of the XY-122.
! Hole layout (pitch): 127 mm × 70 mm (5 in. × 2.8 in.)
! Be sure to use wall mount brackets that have enough strength to be able to withstand the weight of the XY-122.
To rotate the HF waveguide
1
Using a 5 mm Allen key, unscrew the four M6 machine screws in the top and bottom of the enclosure (2 at each end). Gently remove the grille from the front of the
enclosure.
2
Using a 4 mm Allen key, remove the eight countersunk bolts holding the HF waveguide in place.
3
Lift the waveguide up and rotate to the desired position — the label on the waveguide shows the dispersion orientation.
4
Reinstate the socket-head bolts and retighten. Avoid over-tightening as this may crack the waveguide.
5
Reinstate the grille by gently placing it in place over the front of the loudspeaker. Replace the four M4 machine screws to secure it in place.
Using the supplied M10 socket head bolts, bolt through the CP-XY12DF1 plate into
the enclosures. Ensure that both the flat and spring washers are used — the flat
washer should be in contact with the plate. Once the desired angles of the loud-
speakers are set, tighten the bolts to lock in place. Then turn the cluster over and
repeat the process on the bottom. Use the rear points on the XY-122 enclosures, or
the M10 holes on the CP-XY12DF1 plates to use as a secondary safety feature.