Dinel ULM-53L-20 Manuel d'instruction - Page 5

Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} Dinel ULM-53L-20. Dinel ULM-53L-20 16 pages. Ultrasonic level meters

Dinel ULM-53L-20 Manuel d'instruction
3 .  m
easUring
The  ULM
  ultrasonic  level  meters  are  compact  measurement  devices  containing  an  ultrasonic 
®
transmitter  and  an  electronic  module.  Using  an  transmitter,  level  meters  transmit  the  series  of 
ultrasonic  pulses  that  spread  towards  the  level  surface.  The  transmitter  recuperates  reflected 
acoustic waves that are subsequently processed in the electronic module. Based on the period 
during which the individual pulses spread towards the level and back, this period is averaged by 
the  electronics  that  performs  temperature  compensation  and  subsequently  a  conversion  to  an 
output current (voltage) or Modbus communication.
4 .  r
ange
of
aPPlication
The level meters are suited to continuous non-contact level measurement of liquids (water solu-
tions, sewerage water, etc.), mash and paste materials (sediments, sticks, resins etc.) in closed 
or open vessels, sumps, reservoirs and open channels. In case the level of bulk-solid materials is 
measured, the measurement range is reduced. 
ULM–53L–__–I  and  ULM–53L–__–U  level  meters  has  no  customer  accessible  adjusting  ele-
ments. Customer choice of the maximum measurement range (factory settings), The outputs can 
be current (4 ... 20 mA) or voltage (0 ... 10 V). ULM–53L–__–M level meters has no customer 
accessible adjusting elements. Two-way communication (parameterization) by RS–485 Modbus 
RTU protocol.
5 .  f
eatUres
of
ULM –53L –02
ULM –53L–06
ULM –53L–10
ULM–53L–20
© Dinel, s.r.o.
ULM–53L
PrinciPle
variants
Measuring range from 0.25 m to 2 m (customer configurable), plastic 
PVDF (Polyvinylidene Fluoride) transmitter and plastic body, process 
connection with thread G 1".
Measuring range from 0.25 m to 2 m (customer configurable), plastic 
PVDF (Polyvinylidene Fluoride) transmitter and plastic body, process 
connection with thread G 1½".
Measuring range from 0.5 m to 10 m (customer configurable), plastic 
PVDF transmitter and plastic body, process connection with PP 
(Polypropylene) flange.
Measuring range from 0.5 m to 20 m (customer configurable), plastic 
PVDF transmitter and plastic body, process connection with 
aluminium flange.
5