b) Mode C (normally closed)
1.
Put the level of the measured medium in the state below the lower edge of the
sensor in the tank or in the gauge-pipe.
2.
Attach the magnetic pen MP-8 to the sensitive spot
When the LED lights up, the sensor is in the state closed.
3.
After removal of the magnetic pen check the status of orange lights:
-
If the LED lights or is flashing rapidly (0.2 s), go to step 4.
-
If the LED doesn´t light, you must repeat step 2 so as to observe the limit
of 4 seconds attaching magnetic pen.
4.
Put the level of the measured medium in the state above the upper edge of the
sensor in the tank or in the gauge-pipe.
5.
Attach the magnetic pen MP-8 to the sensitive spot
When the LED goes out, the sensor is in the state open.
6.
After removal of the magnetic pen check the status of orange lights:
-
If the LED doesn´t light, settings of the sensor is correct.
-
If the LED lights, the sensor was set incorrectly and you must repeat the
procedure from step 1.
-
If the LED is flashing, the sensor didn´t recognize upper and lower limits.
In this case, first verify that at the step 1 the level of the measured medium
was below the lower edge of the sensor and at the step 3 the level of the
measured medium was above the upper edge of the sensor. Then make sure
that the thickness of the gauge-pipe wall or the tank wall does not exceed
the limit specified in the Technical specifications (p. 2). If not, check there
isn´t a thick layer of sediment on the inner wall of the tank or the gauge-pipe.
After this settings the sensor responds to the level immersion and emersion in the
upper half of the sensing area and the hysteresis size 5 mm (1/8 of the distance
between the bottom and the top of the sensor).
S
TaTuS SigNalizaTiON
Indicator
Orange LED
* Sensor with "S" type output, for each flash of the LED switches its output on for approx. 3 ms. This period is
sufficiently short to avoid unwanted switching of relay contacts. For binary inputs, we recommend to set the filter so
as not to respond to pulses shorter than 3 ms.
7
Function
Continuous light – Sensor is closed (switched ON)
Dark – Sensor is open (switched OFF)
Rapid flashing (period 0,2 sec.) * – Unrecognized upper and lower limits of setting mistake
Slow flashing (period 0,8 sec.) – Short circuit at sensor output
for minimum 4 seconds.
M
for maximum 2 seconds.
M