applies: Values greater than 32768 may needed to be given as negative values too.
Parameter 1: Which value of the Sensor Binary Report or Basic Set will be sent when the door is Opened/Clos
To set which value of the Sensor Binary Report or Basic Set will be sent when the door is Opened/Closed.
Size: 1 Byte, Default Value: 1
Setting
0
1
Parameter 39: Set the low battery value.
Set the low battery value.(10% to 50%).
Size: 1 Byte, Default Value: 20
Setting
10 - 50
Parameter 101: Enable/disable the function of parameter 111
Enable/disable the function of parameter 111.Note: this parameter cannot disable the low battery checking of the Sensor itself.
Size: 1 Byte, Default Value: 1
Setting
0
1
Parameter 111: Set the interval time of low battery checking.
Set the interval time of low battery checking.Note:1, if the value is less than 10, the time unit is second.If the value is more than 10, the time unit is 4 minutes, wh
means if the value is more than 10 and less than 240, the interval time is 4 minutes. If the value is more than 240 and less than 480, the interval is 8 minutes.2, if
current battery report falls below the low battery value (configurable parameter 39), it will send battery report=0xFF.
Size: 4 Byte, Default Value: 86640
Setting
0 - 2147483647
Parameter 121: To configure which sensor report will be sent when the door is opened/closed.
To configure which sensor report will be sent when the door is opened/closed.
Size: 1 Byte, Default Value: 1
Setting
1
2
3
Parameter 252: Lock/unlock all configuration parameters.
Lock/unlock all configuration parameters.
Size: 1 Byte, Default Value: 0
Setting
0
1
Parameter 252: Reset to factory defaults.
Size: 4 Byte, Default Value: 0
http://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW112
Description
Sensor Binary Report/Basic Set =0xFF when the door is opened, Sensor Binary Report/Basic Set= 0x00 whe
door is closed.
Sensor Binary Report/Basic Set= 0x00 when the door is opened, Sensor Binary Report/Basic Set=0xFF when
door is closed.
Description
The range of low battery value can be set to 10% to 50%.
Description
Disable.
Enable.
Description
The range of interval can be set to 0 to 2147483647.
Description
Basic Set CC is selected.
Sensor Binary Report CC is selected.
Basic Set CC and Sensor Binary Report CC are selected.
Description
Unlock.
Lock.