Ariston NEXT SFT 14 Manuel de l'utilisateur - Page 35

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Ariston NEXT SFT 14. Ariston NEXT SFT 14 40 pages. Instantaneous multipoint gas water heater type c

6.4 Fault fi nding chart
PRELIMARY CHECKS
Make sure that:
1 - The mains water supply is turned on
2 - The gas is turned on
3 - The electrical supply is turned on
PRESS THE ON/OFF BUTTON
DRAW OFF WATER >2.5 l/min
IS THE AIR º
PRESSURE SWITCH
IN OPEN CIRCUIT?
HAS THE FAN
STARTED TO RUN?
HAS THE
IGNITION SEQUENCE
BEGUN?
IS SPARK
GENERATION
NORMAL?
IS THE BURNER
ALIGHT?
HAS THE
APPLIANCE SAFETY
SHUTDOWN BEEN
ACTIVATED?
A
1 - Check/replace connection cable
2 - Check/replace the air pressure switch
3 - Check/replace the printed circuit board
MOMENTARY
1 - Check/replace connection cable
POWER TO
2 - Check/replace the printed
FAN?
1 - Replace fan
IS FAN
RUNNING
CONTINUOUSLY?
1 - Check air pressure switch
2 - Check venturi & pipes
3 - Check fan efficiency
1 - Check ignition electrode cable
2 - Check/replace ignition electrode
3 - Check/replace the P.C.B.
1 - Check power supply of gas valve
2 - Check operation of gas valve
3 - Replace gas valve
4 - Check/replace the P.C.B.
1 - Check if flame strikes detection electrode
2 - Check/replace detection electrode
3 - Check/replace the P.C.B.
6. maintenance
circuit board
35