Aeotec ZW187 Manuel de l'utilisateur - Page 8
Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Aeotec ZW187. Aeotec ZW187 9 pages. Recessed door sensor gen7
Également pour Aeotec ZW187 : Manuel (11 pages)
Advanced Functions.
Remove your sensor from your Z-Wave network (Software reset).
Your Recessed Door Sensor can be removed from your Z-Wave network at any time. You'll need to use your Z-Wave
network's main controller to do this.
1. Set your Z-Wave Controller into its 'Remove Device' mode in order to remove the product from your Z-Wave
system Refer to the Controller's manual if you are unsure of how to perform this step.
2. Make sure the product is powered.
3. Click Action Button once; LED will become flash Red color for 5 seconds.
4. If Removing fails, it will extinguish, without slow fade-in fade-out Red color.
5. If Removing succeeds, it will become slow fade-in fade-out Red color for 10 seconds, and then extinguish.
Now, it is Roved from Z-Wave network successfully.
Manually Factory Reset your sensor.
If the primary controller is missing or inoperable, you may need to reset the device to factory settings. Make sure the
product is powered. To complete the reset process manually,
Press and hold the Action Button for at least 20 seconds.
@2 seconds, LED will shows a slow pulsing LED
@5 seconds, LED will pulse faster
@10 seconds, LED will flash even faster.
@20 seconds, LED will become solid for 2 seconds to indicate it factory reset.
You can release the action button here.
@22 seconds. LED will breathe slowly to indicate it is factory reset.
Release the Action Button when LED becomes slow fade-in fade-out red color.
Note:
1. This procedure should only be used when the primary controller is missing or inoperable.
2. Factory Reset will:
(a) Remove the product from Z-Wave network;
(b) Delete the Association setting;
(c) Restore the configuration settings to the default.
Wakeup your Recessed Door Sensor for configuration.
You can wakeup Recessed Door Sensor 7 to communicate with your Z-Wave gateway or push configuration settings
to your sensor.
To wake up your sensor, follow these steps:
Press and hold the Action Button for at least 2 seconds, but before 5 seconds.
@2 seconds, LED will shows a slow pulsing LED
Release action button here to toggle 10 minute wakeup.
If successful, LED will remain solid until sensor goes back to sleep.