Aeotec ZWA011 Manuel de l'utilisateur - Page 9

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Aeotec ZWA011. Aeotec ZWA011 9 pages.
Également pour Aeotec ZWA011 : Manuel de démarrage rapide (11 pages)

Aeotec ZWA011 Manuel de l'utilisateur
18/06/2021
0 -
Time in seconds
32400
Parameter 12: Delay of tamper alarm cancellation.
The time period after which a tamper alarm will be canceled.
Size: 2 Byte, Default Value: 0
Setting Description
0 -
Time in seconds
32400
Parameter 13: Reporting tamper alarm cancellation.
Reporting cancellation of tamper alarm to the controller and 3rd Association Group.
Size: 1 Byte, Default Value: 1
Setting Description
0
do not send tamper cancellation report
1
send tamper cancellation report
Parameter 255: Factory reset.
This parameter helps reset configuration parameters and the device to factory defaults.
Size: 1 Byte, Default Value: 0
Setting
Description
1
Reset Parameter
1431655765 Factory default (exclude the device)
https://help.aeotec.com/support/solutions/articles/6000230382-door-window-sensor-7-basic-user-guide-zwa011-zwa041-
Aeotec Door Window Sensor 7 Basic guide : Aeotec Help Desk
9/9