Parameter 111: Set the interval of automatic report for Report group 1.
Set the interval of automatic report for Report group 1.
Size: 4 Byte, Default Value: 3
Setting
1 - 2147483647
Parameter 112: Set the interval of automatic report for Report group 2.
Set the interval of automatic report for Report group 2.
Size: 4 Byte, Default Value: 600
Setting
1 - 2147483647
Parameter 113: Set the interval of automatic report for Report group 2.
Set the interval of automatic report for Report group 3.
Size: 4 Byte, Default Value: 600
Setting
1 - 2147483647
Parameter 120: Configure the external switch mode for S1.
Configure the external switch mode for S1.
Size: 1 Byte, Default Value: 0
Setting
0
1
2
3
Parameter 121: Configure the external switch mode for S2.
Configure the external switch mode for S2.
Size: 1 Byte, Default Value: 0
Setting
0
1
2
3
Parameter 122: Set the control destination for external switch S1
Set the control destination of the external switch.
Size: 1 Byte, Default Value: 3
Setting
1
2
3
Description
The range of interval time is 1 to 2147483647.
Description
The range of interval time is 1 to 2147483647.
Description
The range of interval time is 1 to 2147483647.
Description
Enter automatic identification mode
Momentary push button mode
3 way switch mode
2-state switch mode
Description
Enter automatic identification mode
Momentary push button mode
3 way switch mode
2-state switch mode
Description
control the output loads of itself.
control the other nodes
control the output loads of itself and other nodes.