Initial operating procedures
Check the water pressure on the pressure gauge and make sure
that the figure is between 0.6 and1.5 bar when the system is cold.
If the pressure is just under the minimum value the display will
request a filling procedure - see note below.
FILLING PROCEDURE
RE-ESTABLISH THE CORRECT PRESSURE USING
THE FILLING LOOP (POSITIONED UNDERNEATH THE
BOILER) AND PRESS THE MODE BUTTON FOR 5
SECONDS. THE DISPLAY SHOWS "PURGE".
WHEN THE PRESSURE GAUGE INDICATES A PRESSURE
OF 1 BAR, CLOSE THE FILLING VALVE AND PRESS THE
MODE BUTTON. THE DISPLAY RETURNS TO NORMAL
VIEW.
Re-establish the correct pressure by filling loop.
If the pressure drops very frequently, there may be a water leak
at some point in the system. If this is the case a plumber should
be contacted.
CLAS ONE / CLAS NET ONE
Note.
Note: Connections viewed from behind boiler
Connections viewed from
behind boiler.
CLAS SYSTEM ONE
1
Note.
Note: Connections viewed from behind boiler
Connections viewed from
behind boiler.
1. To repressurise the system ensure flexible hose 3 is
connected
2. Slowly open taps 1 & 2 (see diagrams above)
3. Water will be heard entering the system
4. When the pressure gauge reads 1.5 bar close taps 1 & 2
6
/
2
1
3
2
3
Ignition procedure
Press the ON/OFF button
boiler
The display shows :
- the operating mode:
- the set temperature in central heating mode
- the set temperature of the hot water in domestic hot water
Operating mode selection
Use the MODE button 3 to select the desired operating mode.
Operating mode
heating + hot water production for domestic use -
WINTER
hot water production for domestic use only -
SUMMER
ONLY HEATING
CLAS SYSTEM ONE
The ignition of the burner is indicated on the display by the
symbol
the dashes underneath indicate the power
utilised.
Adjusting the heating
It is possible to set the temperature of the heating water by
pressing the buttons 8.
The temperature that may be obtained.which varies from 20°C
to 45°C (low temperature) and 35°C to 82°C (high temperature).