Ariston ecoGENUS 24 MFFI Instructions d'entretien - Page 11

Parcourez en ligne ou téléchargez le pdf Instructions d'entretien pour {nom_de_la_catégorie} Ariston ecoGENUS 24 MFFI. Ariston ecoGENUS 24 MFFI 32 pages. Condensing type c boilers
Également pour Ariston ecoGENUS 24 MFFI : Manuel de l'utilisateur (28 pages)

Ariston ecoGENUS 24 MFFI Instructions d'entretien
1.5
A
CCESS TO THE
Important! Before any component is removed, the boiler
must be drained of all water.
Removing the D.H.W. (secondary)
exchanger
1. Remove the screw "U" (F
2. Remove the screw "V" (F
3. Push the exchanger towards the rear of the boiler, lift
upwards and remove from the front of the boiler (F
1.34);
4. Before replacing the exchanger ensure that the O-rings
are in good condition and replace if necessary.
F
. 1.32
IG
F
. 1.33
IG
F
. 1.34
IG
W
C
ATER
IRCUIT
. 1.32);
IG
. 1.33);
IG
U
V

Removing the safety valve

1. Loosen union "W" (Fig. 1.35);
2. Unscrew and remove the valve (Fig. 1.36).
.
IG
F
. 1.35
IG
F
. 1.36
IG
W
11