Ariston GENUS 47-116-08 Manuel d'entretien - Page 18
Parcourez en ligne ou téléchargez le pdf Manuel d'entretien pour {nom_de_la_catégorie} Ariston GENUS 47-116-08. Ariston GENUS 47-116-08 44 pages. Type c
18
Supplied By www.heating spares.co Tel. 0161 620 6677
Removing the D.H.W. temperature sensor (N.T.C.)
1. Remove the electrical connector by pulling off the
thermostat connection and unscrew the sensor probe
with a 14 mm open ended spanner (see fig. 1.49) .
Fig. 1.49
Removing the diverter valve (Genus 27 RFFI only)
1. Remove the circlip and pull the diverter valve to the left.
Fig. 1.50
B005