Supplied By www.heating spares.co Tel. 0161 620 6677
Removing the D.H.W. temperature sensor (N.T.C.)
1. Remove the electrical connector by pulling off the
thermostat connection and unscrew the sensor probe
with a 14 mm open ended spanner (see fig. 1.49) .
Fig. 1.49
Removing the diverter valve (Genus 27 RFFI only)
1. Remove the circlip and pull the diverter valve to the left.
Fig. 1.50