Aeotec TriSensor AEOEZWA005 Manuel - Page 4
Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Aeotec TriSensor AEOEZWA005. Aeotec TriSensor AEOEZWA005 7 pages.
19/11/2020
Setting
0
1
Parameter 5: Disable BASIC_SET to Associatednodes
This parameter is configured the enabled or disabled send BASIC_SET command to nodes that associated in group 2 and group 3.
Size: 1 Byte, Default Value: 3
Setting
0
1
2
3
Parameter 6: Basic Set Value Settings for Group 2
Size: 1 Byte, Default Value: 0
Setting
0
1
2
3
4
5
Parameter 7: Temperature Alarm Value
This parameter is configured the threshold value that alarm level for temperature. When the current ambient temperature value is larger than this
configuration value, device will send a BASIC_SET = 0xFF to nodes associated in group 3. If current temperature value is less than this value, device will
send a BASIC_SET = 0x00 to nodes associated in group 3.Value = [Value]0.1(Celsius / Fahrenheit)
Size: 2 Byte, Default Value: 239
Setting
-400 - 850
Parameter 10: Led Indicate Disable
This parameter is configured the Led light on disable or enable. This configuration is not affect inclusion, exclusion and reset.
Size: 1 Byte, Default Value: 1
Setting
0
1
Parameter 11: Led Color For Motion EventReport
Size: 1 Byte, Default Value: 2
Setting
0
1
2
3
4
5
6
7
8
manuals-backend.z-wave.info/make.php?lang=en&sku=AEOEZWA005&cert=ZC10-18046087&type=mini
manuals-backend.z-wave.info/make.php?lang=en&sku=AEOEZWA005&cert=ZC10-18046087&type=mini
Description
Disable sensor binary report when motion event is detected or cleared.
Enable sensor binary report when motion event is detected or cleared.
Description
Disabled All Group Basic Set Command
Enabled Group 2 Basic Set Command, Group 3 Basic Set Command is disabled.
Enabled Group 3 Basic Set Command, Group 2 Basic Set Command is disabled.
Enabled Group 2 and Group 3 Basic Set Command.
Description
Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is triggered, send
BASIC_SET = 0x00 to devices associated in group 2 when motion event is cleared.
Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is triggered, send
BASIC_SET = 0xFF to devices associated in group 2 when motion event is cleared.
Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is triggered.
Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is triggered.
Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is cleared.
Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is cleared.
Description
Value = 0.1(Celsius / Fahrenheit)
Description
Disable Led Blink.
Enable Led Blink when device detects a motion event.
Description
Disable
Red
Green
Blue
Yellow
Pink
Cyan
Purple
Orange
4/7