Built-in installation of FC 97 P (see figure on the right)
1. Place brackets "A" well against the oven support blocks
"B".
2. Place the tabs "C" well against brackets "A". In particular,
if the cabinet side panel:
• is 16 mm thick: mount the tab so that the number 16 it
features is facing you;
• is 18 mm thick: mount the tab so that the part without
any wording is facing you;
• is 20 mm thick: do not mount the tab.
3. Fasten the brackets and tabs on the oven cabinet side
panel using screws "D".
4. Fasten the oven to the cabinet using the screws and
plastic washers "E".
Connection
First check the mains electricity supply available (number
of phases - voltage - maximum power necessary) to
ensure these are compatible with the requirements of the
Ariston appliance to be connected.
Ariston ovens can adapt to the following electrical systems:
Electrical connections
N
L
L2
L1
You can connect your furnace to the electric installation
by means of a case of connection. You defer to the table
for the minimal wire sections and the calibration of the
protection measures according to the branch.
If the appliance is installed with a junction box, an
omnipolar circuit breaker - with a minimum contact opening
of 3 mm - should be installed between the appliance and
the mains.
We recommend you use a power supply cable which is
long enough to allow you to take the oven out of its recess
in the event of maintenance operations (only use HAR -
H 05 - RRF quality cables fitted with a plug conforming to
the regulations in force in the country where the appliance
is fitted).
The plug must be accessible at all times.
Unplug the appliance before all operations, even when
replacing the oven lamp.
Installation

Electrical connection

Voltage
Fuse
Frequency
Section
FR-AT-BE-DE-GP-ES-IE-IL-IS-IT-DK
LU-RE-FI-GB-GR-PT-SE-MA-NZ-NL
230 V-1+N ~ 50 Hz
16 A
1,5 mm²
CY-MT-AU-NZ-KW
240 V-1+N ~ 50 Hz
FR-BE-NO
16 A
1,5 mm²
230 V-2 ~ 50 Hz
C
D
A
D
C
C
D
B
Using the appliance without correct earthing is highly
dangerous.
Important: After connecting the appliance to the flexible
cable, tighten all the screws on the terminal board.
This appliance conforms with the following European
Community directives:
DBT 73/23 EEC modified by 93/68/EEC directive
CEM 89/336/EEC modified by 92/31/EEC and 93/68/EEC
directives
Inner dimensions of the oven:
width
depth
height
Inner volume of the oven:
Voltage and frequency of power supply:
37
E
E
43.5 cm
40.0 cm
32.0 cm
54 litres
230V~50Hz : 2800 W
240V~50Hz : 3050 W