2.5 PRODUCT CHARACTERISTICS:
SURROUND:
The innovative SURROUND refrigeration system
featured on all Ariston Full No Frost refrigerators
guarantees a uniform temperature throughout the
refrigeration compartment thanks to numerous
ventilation cells.
It is easy to identify since inside the fridge an
extension of the multiflow which reaches to the
very roof of the compartment is clearly visible.
The Surround system It is managed by the
appliance's main PCB which controls a stepper
type electronic damper with three positions:
a. Closed: when there is no cooling demand from the
fridge compartment. In this case there is no air
circulation inside the compartment.
b. Open 45°: which allows circulation of air through
the multiflow column. This grading occurs when
the user selects any function other than I CARE or
Super Fridge, and therefore, the SURROUND
system is not activated.
c. Open 90°: In this case the SURROUND system is
active and the four vents are operational (with air
flow). The electronic circuit board will open the
Damper at 90°. The SURROUND system will be
activated by the PCB automatically if the user has
set the I CARE and/or Super Fridge function on
the control panel.
Control Care Zone (C.C.Z.):
The Control Care Zone (C.C.Z.) or variable
temperature compartment is an area of the
freezer (top drawer) which allows the user to set a
different temperature compared to the rest of the
freezer compartment (which will operate as a
normal freezer). The setting options are: -8°C
represented by the STRAWBERRY symbol,
Service Manual
NEW ARISTON 60 cm PLATFORM
-12°C represented by the ICE CREAM and, -18°C
represented by a BOTTLE.
Note.: with C.C.Z. switched off, the drawer in
question operates as a normal freezer
compartment drawer, both in Static and No
Frost appliances.
Edition