Burner and nozzle specifications
Auxiliary Burner
Semi Rapid Burner
Rapid Burner
Dual Control Wok Burner
Total
Gas Connection
Gas Inlet fitting
Location of gas inlet
A
R
DC
S
PK 640 R GH AUS
Burner and nozzle specifications
Auxiliary Burner
Semi Rapid Burner
Wok Burner
Dual Control Wok Burner
Total
Gas Connection
Gas Inlet fitting
Location of gas inlet
S
DC
TC
A
PK 750 RT GH AUS
! The product was tested in accordance with AS4551 standard
Natural Gas (1.0 kPa)
Ø Injector (mm)
0.85
1.10
1.24
0.80 + 1.19 + 1.19
1/2" BSP (male) thread
40 mm from rear edge
40 mm from right hand edge
Natural Gas (1.0 kPa)
Ø Injector (mm)
0.85
1.10
1.19 (x2)
0.80 + 1.19 + 1.19
1/2" BSP (male) thread
40 mm from rear edge
40 mm from right hand edge
GC (MJ/hr)
Ø Injector (mm)
3.6
0.50
6.0
0.64
7.8
0.80
17.0
0.50 + 0.70 + 0.70
34.4
GC (MJ/hr)
Ø Injector (mm)
3.6
0.50
6.0
0.64
13.5
0.70 (x2)
17.0
0.50 + 0.70 + 0.70
40.1
ULPG (2.75 kPa)
GC (MJ/hr)
3.3
5.5
9.0
16.5
34.3
ULPG (2.75 kPa)
GC (MJ/hr)
3.3
5.5
13.0
16.5
38.3