Technical data
Dimensions
Height
Width
Depth
Weight
Without packing
Main Connection
Voltage
Frequency
Power consumption
Fuse rating
Drum
Volume
Washing
Ramp spin
Speed spinning max.
Capacity of dry laundry
Cotton/coloured
Cotton rapid
Daily
Cotton short
Easy care
Easy care rapid
Easy care short
Delicate
Wool
Water Level
Level 1
Switching point
Switching back point
Overflow
Water level inside the drum
(only switching level inside the drum)
Level 1
Overflow
AWO 5761
8592 113 53000
85
cm
59.5
cm
60
cm
73
kg
240
V
50
Hz
2.3
kW
10
A
53
l
54
rpm
95
rpm
1400
rpm
6
kg
3
kg
3
kg
6
kg
2.5
kg
1.5
kg
2.5
kg
1.5
kg
1
kg
55 ± 5
mmWc
35 ± 5
mmWc
300 ± 20 mmWc
25 - 39
mm
267 - 306 mm
Whirlpool Europe
Customer Service
Nominal currents
Contacts
11 - 12
11 - 14
11 - 16
Contact system
11 - 12 - 14
11 - 16
Door lock
Lock time (20 ˚C)
Unlock time
Nominal voltage
Nominal current:
Contact 4 - 5
Heating element
Kind of heating
Nominal Voltage
Nominal power
resistance R25
Resistance NTC:
0 ˚C
30 ˚C
40 ˚C
50 ˚C
60 ˚C
70 ˚C
95 ˚C
Inlet valve cold/hot fill
Water temperature max.
Rated flow <1 bar
Pressure range
Nominal voltage
Frequency
Starting voltage:
<6 bar
6 - 10 bar
Nominal current
Nominal power
Nominal resistance (20 ˚C) 3.4 - 4.5
Switch aquastop
Nominal voltage
Nominal current
Switch energy
S E R V I C E
4 (4)
A
16 (4)
A
1 (1)
A
spring contact
sliding contact
3" - 6''
60" - 90''
230
V
16 (4)
A
Tubular heating element
with NTC - sensor
240
V
2050
W
Ω
22 - 28
35.9
kΩ
9.8
kΩ
6.6
kΩ
4.6
kΩ
3.2
kΩ
2.3
kΩ
1.1
kΩ
60
˚C
4
l/min
0.5 - 10
bar
220 - 240 V
50
Hz
160
V
170
V
35
mA
6
VA
kΩ
230
V
3 (1)
mA
<15
cN