Ariston PK 644D GH X LPG Manuel d'utilisation - Page 16

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Ariston PK 644D GH X LPG. Ariston PK 644D GH X LPG 45 pages.

Ariston PK 644D GH X LPG Manuel d'utilisation
Gas tap maintenance
GB
Over time, the taps may become jammed or difficult to turn.
If this happens, the tap must be replaced.
! This procedure must be performed by a qualified
technician authorised by the manufacturer.

Troubleshooting

It may happen that the appliance does not function properly
or at all. Before calling the service centre for assistance,
check if anything can be done. First, check to see that there
are no interruptions in the gas and electrical supplies, and,
in particular, that the gas valves for the mains are open.
The burner does not light or the flame is not even
around the burner.
Check whether:
• The gas holes on the burner are clogged.
• All the movable parts that make up the burner are
mounted correctly.
• There are draughts near the appliance.
The flame dies in models with a safety device.
Check to make sure that:
• You pressed the knob all the way in.
• You keep the knob pressed in long enough to activate
the safety device.
• The gas holes are not blocked in the area corresponding
to the safety device.
The burner does not remain lit when set to minimum.
Check to make sure that:
• The gas holes are not blocked.
• There are no draughts near the appliance.
• The minimum setting has been adjusted properly.
The cookware is unstable.
Check to make sure that:
• The bottom of the cookware is perfectly flat.
• The cookware is positioned correctly at the centre of the
burner.
• The pan support grids have been positioned correctly.
16