7. HEATER & THERMOSTAT ASSEMBLY
1
• To access the Heating Element or Thermostats remove the Rear Access Panels (Fig. 7-1) in this order; Bearing Cover (1), Panel
Support (2) and then the Rear Cover (3). With the Rear Access Panels removed you have access to the following components.
A. Drum Bearing Block
B. Thermostat Assembly
C. Heating Element
D. Blower Fan Blade
• The Heating Element is held in place using a tab and slot configuration (Fig. 7-3). To remove, release the left and right tabs and
then slide the Heating Element up and out of its slot. The Thermostats (Fig. 7-4) are each held in place with two (2) Phillips screws,
remove the screws and replace the Thermostat.
REPAIR MANUAL
2
3
Fig. 7-1
Fig. 7-3
A
C
D
A
THERMOSTATS:
A. High Limit, non-resetable 250˚f
B. Cycling, 185˚f
A 45 V
B
Fig. 7-2
B
Fig. 7-4