Installation Instructions
Read these instructions with care.
These instructions are provided for use by qualified installers, in addition the installation must comply with:
In the United States, in accordance with the National Electric Code ANSI/NFPA70 – latest edition and any State,
Municipal or local codes.

Electrical

The dryer comes with a three cord power supply cord fitted with a 5-15P (plug), a receptacle should be installed in a
location accessible after the dryer is installed.
Grounding
Some local codes may require a separate ground. In such cases the required ground wire, clamp and screw
must be purchased separately.
NEVER ground the dryer to plastic plumbing lines, gas lines or water pipes.
NOTE: IF IN DOUBT ABOUT ANY OF THE ABOVE
CONSULT A QUALIFIED ELECTRICIAN

Where to put your dryer

Check local codes before choosing a location. Some codes do not permit installation in a garage, closet, mobile home or
bedroom.. DO NOT install the dryer in an area where gasoline or other flammable materials are kept or stored.
When operating the dryer, there has to be adequate ventilation to avoid the back flow of gases into the room from
appliances burning other fuels, including open fires.
Minimum installation clearances.
Sides
Top
Rear
Front
Vent Opening –
Distance from
Top of closet
If installed in a closet it must have the following dimensions and have two ventilation openings each having and area 72
sq. ins. (450 sq. cm) located) 2" (50mm or 6" (150mm) from top[see table] and 6" (150mm) from bottom of door.
It must NEVER be installed in a closet with a solid door.
The dryer has adjustable height feet, use these to level the dryer after fitting into its final position.
RV/Marine Installations - When locating the appliance in a towable trailer or watercraft, position the
machine over the axles or mid-ship where movement is at a minimum. Block the machine to prevent
extreme movement or tipping.
www.aristonappliances.us
10
Closet
Closet (alternative)
¾" (15 mm)
0
4"
½" (10 mm)
5" (100 mm)
¾" (15 mm)
¾" (15 mm)
¾" (15 mm)
¾" (15 mm)
6" (150mm)
2" (50mm)
Under Counter
¾" (15 mm)
½" (10 mm)
¾" (15 mm)
not applicable
not applicable
10