8. Remove aluminium tape that cover
electrical wire.
Part Name
Bimetal Thermo
2.Pull out socket of Bimetal Thermostat.
5. Cut out Cable Tie from Evaporator
tube.
Ref. No. : SM77-05-058-0
9. Hold Glass Tube Heater at the rubber
connector.
Operating Procedure
1. Follow step 1-11 of replacing Fan Motor.
3. Use small steel stick to press at the
Recept Terminal while pull out electrical
wire.
6. Remove Bimetal Thermostat.
10. After replacing Glass Tube Heater,
reverse the steps above.
4. Pull out electrical wire from socket.
7. After replacing Bimetal Thermostat,
reverse the steps above.