Whirlpool WUR50X24EM00 Manuel d'utilisation et d'entretien - Page 4

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation et d'entretien pour {nom_de_la_catégorie} Whirlpool WUR50X24EM00. Whirlpool WUR50X24EM00 12 pages. Under counter refrigerator

Whirlpool WUR50X24EM00 Manuel d'utilisation et d'entretien
INSTALLATION
INSTRUCTIONS

Location Requirements

WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from refrigerator.
Failure to do so can result in death, explosion, or fire.
To ensure proper ventilation for your refrigerator, allow for a
¹/₄" (6.35 mm) space on each side and at the top. When installing
your refrigerator next to a fixed wall, leave 2¹⁄₂" (6.35 cm)
minimum clearance on the hinge side to allow for the door to
swing open.
NOTE: It is recommended that you do not install the refrigerator
near an oven, radiator, or other heat source. Do not install in a
location where the temperature will fall below 55°F (13°C). For
best performance, do not install the refrigerator behind a cabinet
door or block the base grille.
¹⁄₄
" (6.35 mm)
Opening Dimensions
Height dimensions are shown with the leveling legs extended
to the minimum height.
NOTE: When leveling legs are fully extended, add ⁵⁄₈" (1.6 cm)
to the height dimensions. See "Product Dimensions."
4 4 4 4 4 4 4 4 4 4 4 4
¹⁄₂
2
" (6.35 cm)
If the floor of the opening is not level with the kitchen floor,
shim the opening to make it level with the kitchen floor.
³⁄₄
14
"
(37.5 cm)
A
¹⁄₂
"
(1.3 cm)
24"
(60.96 cm)
min.
24" (60.96 cm) min.
Critical Dimensions:
³⁄₄
A. 14
" (37.5 cm) utility opening
B. 24" (60.96 cm) minimum opening width

Electrical Requirements

WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Before you move your refrigerator into its final location,
it is important to make sure you have the proper electrical
connection.
Recommended grounding method
A 115 Volt, 60 Hz., AC only, 15- or 20-amp fused, grounded
electrical supply is required. It is recommended that a separate
circuit serving only your refrigerator be provided. Use an outlet
that cannot be turned off by a switch. Do not use an extension
cord.
NOTE: Before performing any type of installation, cleaning, or
removing a light bulb, unplug refrigerator or disconnect power.
³⁄₈
34
" (87.3 cm) min.
35" (88.9 cm) max.
B