Whirlpool  WED9051YW Manuel d'instructions d'installation - Page 12

Parcourez en ligne ou téléchargez le pdf Manuel d'instructions d'installation pour {nom_de_la_catégorie} Whirlpool  WED9051YW. Whirlpool  WED9051YW 20 pages. Installation guide
Également pour Whirlpool  WED9051YW : Manuel d'utilisation et d'entretien (20 pages)

4.
Connect neutral ground wire and
neutral wire
Connect neutral ground wire (E) and place hooked end (hook
facing right) of neutral wire (white or center wire) (C) of direct
wire cable under center screw of terminal block (B). Squeeze
hooked ends together and tighten screw.
5.
Connect ground wire
A
F
Connect ground wire (green or bare) (F) of direct wire cable
to external ground conductor screw (A). Tighten screw.
6.
Connect remaining wires
Place hooked ends of remaining direct wire cable wires under
outer terminal block screws (hooks facing right). Squeeze
hooked ends together and tighten screws. Finally, reinsert tab
of terminal block cover into slot of dryer rear panel. Secure
cover with hold-down screw. Now, go to "Venting Requirements."
12
3-WIRE DIRECT WIRE
CONNECTION
Use where local codes permit connecting
cabinet-ground conductor to neutral wire.
B
1.
Prepare your 3-wire cable for
E
direct connection
C
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer may be moved if needed.
Strip 3
/
" (89 mm) of outer covering from end of cable. Strip
1
2
insulation back 1" (25 mm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape wire ends
into hooks.
2.
Attach hooked wires to terminal
block
To connect wires to terminal block, place hooked end of
wire under terminal block screw, facing to the right, squeeze
hooked end together and tighten screw.
3.
Remove center screw
Remove center terminal block screw (B).
B