Whirlpool  WED97HEXL Manuel de l'utilisateur - Page 10

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Whirlpool  WED97HEXL. Whirlpool  WED97HEXL 24 pages. Electronic dryer
Également pour Whirlpool  WED97HEXL : Manuel d'instruction (8 pages), Manuel d'utilisation et d'entretien (36 pages)

Whirlpool  WED97HEXL Manuel de l'utilisateur

Direct Wire Connection

Direct wire strain relief
1.
Attach direct wire strain relief
Unscrew the removable conduit connector (A) and any
screws from a 3/4" (19 mm) UL listed strain relief (UL marking
on strain relief). Put the threaded section of the strain relief
(C) through the hole below the terminal block opening (B).
Reaching inside the terminal block opening, screw the
removable conduit connector (A) onto the strain relief threads
and tighten securely.
2.
Attach direct wire cable to strain relief
Put direct wire cable through the strain relief. The strain
relief should have a tight fit with the dryer cabinet and be in
a horizontal position. Tighten strain relief screw against the
direct wire cable.
If your wiring looks like this:
4-wire direct connection:
Go to 4-Wire Direct Connection on
this page.
3-wire direct connection:
Go to 3-Wire Direct Connection on
page 11.
10
4-Wire Direct Wire connection
ImPoRTAnT: A 4-wire connection is required for mobile homes
and where local codes do not permit 3-wire connections.
1.
Prepare your 4-wire cable
for direct connection
A
B
C
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer may be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable,
leaving bare ground wire at 5" (127 mm). Cut 1
from remaining 3 wires. Strip insulation back 1" (25 mm).
Shape ends of wires into hooks.
2.
Prepare to connect neutral ground
wire and neutral wire
E
Remove center terminal block screw (B). Remove neutral
ground wire (E) from green external ground conductor
screw (A).
/
" (38 mm)
1
2
B
A