The angled hood style (shown following) is acceptable.
10.2 cm
(4")
See the exhaust vent length chart that matches your hood type
for the maximum vent lengths you can use.
Exhaust systems longer than specified will:
■ Accumulate lint, creating a potential fire hazard.
■ Shorten the life of the dryer.
■ Reduce performance, resulting in longer drying times and
increased energy usage.
3. Determine the number of elbows needed.
NOTE: Do not use vent runs longer than specified in the Vent
Length Chart.
The following chart helps you determine your maximum vent
length based on the number of 90° turns or elbows you will
need and the type of vent (rigid or flexible metal) and hood
that you will use.
Install Vent System
1. Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood.
2. Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 10.2 cm (4") clamp.
3. Run vent to dryer location. Use the straightest path possible.
See "Vent System Length." Avoid 90º turns. Use 10 cm (4")
clamps to seal all joints. Do not use duct tape, screws or
other fastening devices that extend into the interior of the vent
to secure vent.
Install Leveling Legs
WARNING
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
1. Open dryer door and remove drying rack, if included. Wipe
drum with damp cloth to remove any dust.
6
6.4 cm
¹ ₂
(2
")
INSTALLATION INSTRUCTIONS
Vent Length Chart
Number of Type of vent
90º turns
or elbows
0
Rigid metal
Flexible metal
1
Rigid metal
Flexible metal
2
Rigid metal
Flexible metal
3
Rigid metal
Flexible metal
4
Rigid metal
Flexible metal
NOTE: Side and bottom exhaust installations have a 90º turn
inside the dryer. To determine maximum exhaust length, add one
90º turn to the chart.
The maximum length using a 5.1 cm x 15.2 cm (2" x 6")
rectangular vent with 2 elbows and a 6.4 cm (2-1/2") exhaust
hood is 2.4 m (8 ft.).
For exhaust systems not covered by exhaust vent length charts
(such as multiple unit hookups, plenums, and power-assist fans),
see Service Manual, Part No. 603197. (To purchase the Service
Manual, contact your local authorised service company).
2. Take two cardboard corners from dryer carton and place them
on floor in back of dryer. Firmly grasp body of dryer and
gently lay it on its back on the cardboard corners.
3. Start to screw legs into holes by hand. Use an adjustable
wrench or 2.5 cm (1") hex-head socket wrench to finish
turning legs until you reach the ridge with the diamond
marking.
A
A. diamond marking
4. To protect the floor, use a large flat piece of cardboard from
the dryer carton. Stand dryer up on the cardboard.
Box or
Angled
louvered
hoods
hoods
15.8 m (52 ft.)
13.4 m (44 ft.)
9.4 m (31 ft.)
7.0 m (23 ft.)
13.4 m (44 ft.)
11.0 m (36 ft.)
7.9 m (26 ft.)
5.5 m (18 ft.)
11.0 m (36 ft.)
18.5 m (28 ft.)
6.7 m (22 ft.)
4.3 m (14 ft.)
8.2 m (27 ft.)
6.4 m (21 ft.)
6.1 m (20 ft.)
3.7 m (12 ft.)
6.1 m (20 ft.)
4.3 m (14 ft.)
5.5 m (18 ft.)
3.0 m (10 ft.)