Whirlpool CABRIO WGD8200YW0 Manuel d'instructions d'installation - Page 5
Parcourez en ligne ou téléchargez le pdf Manuel d'instructions d'installation pour {nom_de_la_catégorie} Whirlpool CABRIO WGD8200YW0. Whirlpool CABRIO WGD8200YW0 36 pages. Gas dryer
Également pour Whirlpool CABRIO WGD8200YW0 : Manuel d'utilisation et d'entretien (36 pages)
Optional Equipment: (Not supplied with dryer)
Refer to your "Use and Care Guide" for information about
accessories available for your dryer.
LOCATION REQUIREMENTS
You will need:
A location allowing for proper exhaust installation.
■
See "Venting Requirements".
A separate 15 or 20-amp circuit needed for gas dryers and
■
30-amp circuit needed for electric dryers.
If using power supply cord, a grounded electrical outlet
■
located within 2 ft. (610 mm) of either side of dryer.
See "Electrical Requirements".
Floor must support dryer weight of 200 lbs. (90.7 kg).
■
Also consider weight of companion appliance.
Level floor with maximum slope of 1" (25 mm) under entire
■
dryer. If slope is greater than 1" (25 mm), install Extended
Dryer Feet Kit, Part Number 279810. If not level, clothes
may not tumble properly and automatic sensor cycles may
not operate correctly.
For garage installation, place dryer at least 18" (460 mm)
■
above floor. If using a pedestal, you will need 18" (460 mm)
to bottom of dryer.
Steam models only: Cold water faucets located within 4 ft.
■
(1.2 m) of the water fill valves, and water pressure of 20-100
psi (137.9-689.6 kPa). You may use the water supply for your
washer using the "Y" connector provided.
Do not operate your dryer at temperatures below 45° F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic sensor cycle. this can result in longer drying times.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check codes requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the
same closet as a dryer.
INSTALLATION CLEARANCES
The location must be large enough to allow the dryer door
to open fully.
DRYER DIMENSIONS
Dryer with extended back:
30"
(783 mm)
43
"
/
1
2
(783 mm)
NOTE: Most installations require a minimum of 5" (127 mm)
clearance behind dryer for exhaust vent with elbow. See "Venting
Requirements".
Spacing for recessed area or closet installation
All dimensions show recommended spacing allowed, with tested
spacing of 0" (0 mm) clearance on sides and rear.
Additional spacing should be considered for ease of
■
installation and servicing.
Additional clearances might be required for wall, door, and
■
floor moldings.
Additional spacing should be considered on all sides of the
■
dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation
■
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilitation openings are
acceptable.
Companion appliance spacing should also be considered.
■
Recessed area
18"*
(457 mm)
1"
1"
29"
(25 mm)
(25 mm)
(737 mm)
Side view - closet or confined area
(Dryer with flat back)
14" max.*
(356 mm)
1"
5"
28"
(25 mm)
(127 mm)
(711 mm)
* Required spacing
Dryer with flat back:
22
/
"
28"
1
4
(565 mm)
(711 mm)
Side view - closet or confined area
(Dryer with extended back)
14" max.*
(356 mm)
1"
5"
30"
(25 mm)
(127 mm)
(783 mm)
Closet door with vents
48"
*
2
(310 cm
2
)
3"*
(76 mm)
3"*
(76 mm)
24"
*
2
(155 cm
)
2
5