Installed in a confined area:
If the dryer is installed in a confined area such as a bathroom
or closet, provision must be made for enough air for
combustion and ventilation. Check governing codes and
ordinances or refer to the "Recessed Area and Closet
Installation Instructions"
in the "Location Requirements"
section.
Gas Supply
Pressure
Testing
A 1A" NPT minimum plugged tapping, accessible for gauge
testing, must be installed immediately upstream of the installed
shut-off valve to the dryer.
The dryer must be disconnected
from the gas supply piping
system during any pressure testing of the system at test
pressures in excess of 1Z2" p sig.
Fire Hazard
Use a heavy metal vent,
Do not use a plastic vent.
Do not use a metal foil vent,
Failure to follow these instructions can result in death
or fire.
WARNING;
To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
[]
The dryer vent must not be exhausted into any gas vent,
chimney, walt, ceiling, attic, crawtspace, or a concealed space
of a building.
[]
Only rigid or flexible metal duct shall be used for exhausting.
[]
Do not use an exhaust hood with a magnetic latch.
[]
Do not install flexible metal vent in enclosed walls, ceilings,
or floors.
[]
4" (102 mm) heavy metal vent and clamps must be used. Do
not use plastic or metal foil vent.
[]
Use clamps to seat all joints. The duct shall not be assembled
with screws or other fastening means that extend into the
duct and catch lint. Do not use duct tape.
[]
The total length of flexible metal vent shall not exceed 7s/4ft
(2.4 m).
iMPORTANT: Observe all governing codes and ordinances.
Rigid metal vent is recommended to prevent crushing and
kinking.
Flexible metal vent must be fully extended and supported when
the dryer is in its final position. Remove excess flexible metal vent
to avoid sagging and kinking that may result in reduced airflow
and poor performance.
An exhaust hood should cap the vent to prevent rodents and
insects from entering the home or business.
Exhaust hood must be at least 12" (305 mm) from the ground
or any object that may be in the path of the exhaust (such as
flowers, rocks, or bushes).
If using an existing vent system, clean lint from the entire length
of the system and make sure exhaust hood is not plugged with
lint. Replace any plastic or metal foil vent with rigid metal or
flexible metal vent.
Plan installation to use the fewest number of elbows and turns.
Exhaust A ir Flow
A. Good
B. Better
Allow as much room as possible when using elbows or making
turns. Bend vent gradually to avoid kinking.
Vent outlet is located at the back of the dryer, at bottom center.
The vent can be routed up, down, left, right, or straight out the
back of the dryer.
Vent System
Length
Maximum length of vent system depends upon the type of
vent used, number of elbows, and type of exhaust hood.
The maximum length for rigid vent is shown in the chart.
Maximum
Vent Length
4" (102 mm) Diameter Exhaust Hoods
Rigid Metal Vent
No. of 90 ° turns
Box Hood and Louvered Style
Angled Hood Style
0
64 ft. (19.5 m)
58 ft. (17.7 m)
1
54 ft. (16.5 m)
48 ft. (14.6 m)
2
44 ft. (13.4 m)
38 ft. (11.6 m)
3
35 ft. (10.7 m)
29 ft. (8.8 m)
4
27 ft. (8.2 m)
21 ft. (6.4 m)
For vent systems not covered by the vent specification
chart,
see your parts distributor.
If dryer is installed in a confined area, such as a bedroom,
bathroom, or closet, provision must be made for enough air
for combustion and ventilation. (Check governing codes and
ordinances.) See "Recessed Area and Closet Installation
Instructions" in the "Location Requirements" section.
A 4" (102 mm) outlet hood is preferred. However, a 21/2 `' (64 mm)
outlet exhaust hood may be used. A 21/2 `' (64 mm) outlet creates
greater back pressure than other hood types. For permanent
installation, a stationary vent system is required.
11