Whirlpool 30" (76.2 cm) Cooktop Manuel d'installation et d'utilisation - Page 8

Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'utilisation pour {nom_de_la_catégorie} Whirlpool 30" (76.2 cm) Cooktop. Whirlpool 30" (76.2 cm) Cooktop 24 pages. 30" (76.2 cm) wall-mount canopy range hood
Également pour Whirlpool 30" (76.2 cm) Cooktop : Manuel d'utilisation et d'entretien (16 pages), Manuel (28 pages)

Whirlpool 30
2. To wire through top:
Mark a line 7½" (19 cm) from the right of the centerline on the
underside of the cabinet. Mark the point on this line that is
2" (5 cm) from back wall. Drill a 1¼" (3 cm) diameter hole
through the cabinet at this point.
To wire through rear wall:
Mark a line 7½" (19 cm) from the right of the centerline on the
wall. Mark the point on this line that is 65¼" (165.7 cm) from
the floor [or ¾" (1.9 cm) from underside of cabinet]. Drill a
1¼" (3 cm) diameter hole through wall at this point.
65 / "
(165.7 cm)
to floor
Style 1 - Cut Openings for 3¼" x 10" (8.3 cm x 25.4 cm)
Rectangular Vent Sytem
Roof Venting
To make a 4" x 10½" (10.2 cm x 26.7 cm) rectangular cutout on
the underside of cabinet top and bottom:
1. Mark lines 1½" (3.8 cm) and 5½" (14 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
4. Repeat steps 1-3 for the underside of the top of the cabinet
Cabinet cutouts
*From wall, not cabinet frame
8
2" (5.1 cm)
7
"
from wall,
(19 cm)
not cabinet
frame
Centerline
" (1.9 cm)
7 "
(19 cm)
Centerline
*1 / " (3.8 cm)
*5 / "
5 / "
(14 cm)
(13.3 cm)
5 / "
(13.3 cm)
Wall Venting
To make a 4" x 10½" (10.2 cm x 26.7 cm) rectangle in the wall:
1. Make 2 lines by measuring from floor 65 " (167.3 cm) and
62 " (158.4 cm) or
" (3.2 mm) and 3 " (9.2 cm) down from
underside of cabinet and mark on the centerline on the back
wall.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the wall.
3. Use saber or keyhole saw to cut a rectangular opening in the
wall for the vent.
Cabinet
front
"
(3.2 mm)
"
(9.2 cm)
Style 2 - Cut Openings for 3¼" x 10" (8.3 x 25.4 cm)
Rectangular Vent to 6" (15.2 cm) Round Vent Transition
Roof Venting
To make a 4" x 10½" (10.2 x 26.7 cm) rectangular cutout on the
underside of cabinet bottom:
1. Mark lines 1½" (3.8 cm) and 5½" (14 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
*5 / "
(14 cm)
*From wall, not cabinet frame
To make a 6 " (15.9 cm) circle on the underside of the cabinet
top:
1. Mark a centerline on the underside of the top of cabinet.
2. Mark a line 4 " (12.1 cm) from the back wall on the underside
of the top of cabinet.
3. Draw a circle using a compass or 6 " (15.9 cm) circle
template.
Centerline
5 "
(13.3 cm)
*1 / " (3.8 cm)
5 / "
(13.3 cm)
5 / "