Whirlpool 99044506A Instructions d'installation et manuel d'utilisation et d'entretien - Page 11

Parcourez en ligne ou téléchargez le pdf Instructions d'installation et manuel d'utilisation et d'entretien pour {nom_de_la_catégorie} Whirlpool 99044506A. Whirlpool 99044506A 28 pages. 30" (76.2 cm) and 36" (91.4 cm) range hood

Reinstall blower
For vented installation only:
IMPORTANT: To avoid damage, do not grasp blower by blower
wheels.
1. Position blower so that blower discharge lines up with
damper/vent connector.
Horizontal Vent
A
A. Blower discharge
2. Slip rods into mounting brackets on blower assembly.
B C
A. Blower
B. Mounting rod
C. Knurled nut
D. Blower wiring plug
3. Securely tighten knurled nuts.
4. Reconnect blower plug.
5. Reinstall bottom cover.
For non-vented (recirculating) installation only:
IMPORTANT: To avoid damage, do not grasp blower by blower
wheels.
1. Move mounting rods to front holes in hood support channels.
2. Position blower so that blower discharge lines up with
louvered opening on hood front.
A. Front holes
B. Blower discharge

Complete Installation

Vertical Vent
A
D
A
B
3. Slip rods into mounting brackets.
4. Securely tighten knurled nuts.
5. Reconnect blower plug.
6. Using a flat-blade screwdriver, pry louver cover off control
panel.
A
7. Reinstall bottom cover.
Install 2 x 75-watt (max.) or 1 x 75-watt and 1 x 25-watt
incandescent light bulbs.
1. Squeeze the plastic lens cover and remove it from the hood.
2. Screw light bulb into socket. If you are using a 25-watt light
bulb as a night light, screw into right-hand socket.
3. Repeat Step 2 for the other light bulb.
4. Replace lens cover by squeezing cover and inserting tabs
into slots.
Install filters
See "Metal Grease Filter" or "Non-vented (recirculating)
Installation Filters" in the "Range Hood Care" section.
B C
D
A. Blower
B. Mounting rod
C. Knurled nut
D. Blower wiring plug
A. Louver cover
A
A
11