Whirlpool AKR 953 Fiche d'installation - Page 9
Parcourez en ligne ou téléchargez le pdf Fiche d'installation pour {nom_de_la_catégorie} Whirlpool AKR 953. Whirlpool AKR 953 10 pages.
Également pour Whirlpool AKR 953 : Fiche d'installation (20 pages)
PRODUCT SHEET
1. Control panel.
2. Grease filter.
3. Halogen bulbs.
4. Steam deflector.
5. Telescopic flue.
To clean the grease filter
Wash the grease filter at least once a month.
1. Disconnect the electrical power supply
2. Remove the grease filters - Fig. 2: pull the spring release
handle (f) downwards, then remove the filter.
3. After cleaning the grease filter refit in reverse order,
making sure the entire extraction surface is covered.
Carbon filter Fitting and Maintenance
Fitting the carbon filter:
1. Disconnect the electrical power supply.
2. Remove the grease filter (f - Fig. 2).
3. Turn the side knobs 90° and then remove the filter holder
(g - Fig. 3).
4. Fit the carbon filter (h - Fig. 3) in the filter holder
(i - Fig. 3).
5. Refit the filter holder and secure it to the hood with the
screw (g - Fig. 3).
6. Refit the grease filter.
Carbon filter maintenance:
Unlike traditional carbon filters, this carbon filter can be
washed and reactivated.
With normal hood use, the filter should be cleaned once a
month. The best way to clean the filter is in a dishwasher at
the highest temperature possible, using a normal dishwasher
detergent. To avoid particles of food or dirt settling on the
filter during washing and giving rise to unpleasant smells, it is
advisable to wash the filter on its own. After washing, dry the
filter in the oven at 100° C for 10 minutes to reactivate it.
The filter will retain its odour-absorbing capacity for three
years, after which it must be replaced.
Replacing bulbs
1. Disconnect the hood from the mains power supply.
WARNING: Wear gloves.
2. Use a small screwdriver to gently prise the lamp cover off
(at the points indicated in Fig. 3).
3. Remove the burnt-out lamp and fit a new one.
WARNING: Replace using 20W max G4 halogen bulbs
only.
4. Close the lighting unit (snap-on).
5019 318 33109
PL
CZ SK
H
CONTROL PANEL
A.
Light ON/OFF switch.
B.
ON/OFF and speed 1 selector switch
(small amount of steam and fumes).
B+D.Speed 2 selector switch
(medium amount of steam and fumes).
Speed 3 selector switch
(large amount of steam and fumes)
BG RO SL
HR GB
Fig. 1
Fig. 2
Fig. 3
Fig. 4
83